»Brochure »Documentation
Measuring standard Glass scale with incremental graduation Accuracy grade ± 3 μm Measuring length ML Metric Mounting spar optional
50 75 100 125 150 175 200 225 250 275 300 325 350 375 425
475 525Measuring length ML Inch 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 18 20
Incremental signals TTL TTL x 5 TTL x 10 Grating period
Integrated interpolation20 μm
without20 μm
5-fold20 μm
10-foldSignal period 20 μm 4 μm 2 μm Measuring step 5 μm 1 μm 0.5 μm Reference marks Distance-coded without load 5.1 V ± 0.1 V/< 180 mA 5.1 V ± 0.1 V/< 220 mA Electrical connection Cable in metal armor, with 9 pin D sub connector; length: 3 m Cable length ≤ 6 m (total length with ACU-RITE cable) Traversing speed ≤ 60 m/min Required moving force ≤ 2.2 N Operating temperature Temperature 0 to +50 °C; humidity 25% to 95% (no condensation forming) Storage temperature Temperature –20 to +70 °C; humidity 20% to 95% (no condensation forming) Protection EN 60 529 IP 53 when mounted according to the mounting instructions Weight 0.5 kg + 0.3 kg/m measuring length